§ 14-16-72. Counterweight hoistways.
A.
Outside counterweight hoistway. Hoistways for counterweights located outside of elevator hoistways shall be kept enclosed for the full height of the shaftway.
Exception: if such hoistways are located outside of the building the shaftway for the counterweight shall be guarded to a height of ten feet above the ground, with solid construction.
B.
Counterweight pit guard. Counterweight hoistways located in the enclosed shaftway of power elevators shall be guarded from a point one foot above the pit floor to a point seven feet above the floor of its own pit or above the floor of the adjacent pit.
Exceptions:
1.
When compensating chains or cables are attached to the underside of the counterweight;
2.
Light weight looped chains may be used where the clearances do not permit the installation of a guard.
C.
Counterweight shaftway doors. Doors leading to counterweight shaftways shall be kept locked.
(Code 1967, § 49-122; Code 1985, § 46-142)